2 0

LIMITS SETUP

Tip:

The gate can be moved electronically with the “Open”, “Stop” and “Close” buttons

on the Control Board or manually by following the instructions on page 11.

! IMPORTANT:

In the event of a complete power failure, including battery backup, the

limits positions may have been cleared and will need to be reset by following the
steps below..

1b

1a

STEP 2

Move the gate at the desired open
position then press and hold the “Open
Limit” button until the LED stops flashing
and illuminates solid.

STEP 3

Move the gate at the desired close
position then press and hold the “Close
Limit” button until the LED stops flashing
and illuminates solid.

“Close Limit” LED
flashes if the close
limit is not set

“Open Limit” LED
flashes if the open
limit is not set.

STEP 1

Connect the “Motor Harness” to the
Control Board.

a. “OPEN RIGHT” Connector if the gate

opens to the Right, when viewed from
inside.

b. “OPEN LEFT” Connector if the gate

opens to the Leftt, when viewed from
inside.