Barrier Arm (B-12) Synchronization Option
NOTE:
The Control Board provides a convenient solution for applications that require
synchronized operation with the Viking Barrier Arm Operator model B-12.
This type of application opens and closes in the follow pattern:
1. Open Command is provided only to the Viking B-12 Barrier Arm Operator.
2. The Barrier Arm will delay to open until this Gate Operator reaches its Open Limit.
3. The Gate Operator will delay to close until the Barrier Arm reaches its Close Limit.
SYNCHRONIZATION WITH B-12
STEP 2
(Figure A)
At the B-12 Barrier Arm Operator,
connect the primary device that will be
used as the OPEN input.
STEP 1
(Figure A & B)
Connect the Gate Operator to the Viking
B-12 Barrier Arm Operator as illustrated.
STEP 4
(Figure C & D)
Connect Viking B-12 Barrier Arm
Operator to the Gate Operator as
illustrated.
STEP 3
(Figure B)
On the Gate Operator Control Board,
activate Sync Mode by placing a jumper
on to the pin headers labeled “SYNC”.
3
1
4
Figure A
Figure B
Figure C
Figure D