beautypg.com

Wiring – Controlled Products Systems Group CSL24V User Manual

Page 22

background image

20

CONNECT BATTERIES

WIRING

33AH BATTERIES

CONNECT BATTERIES

The batteries are charged in the circuit by the integrated transformer. The batteries

are for battery backup or solar installation. The 33AH application requires the 33AH

battery harness (Model K94-36596). NOTE: If 33AH batteries (2) are used, the

battery tray will need to be removed to allow more space in the enclosure.

1

Disconnect the red (+) and black (-) wires going from the bridge rectifier to

the J15 plug labeled DC POWER on the control board.

2

Connect the red (+) and black (-) wires from the new 33AH harness to the

bridge rectifier.

3

Connect a jumper between the positive (+) terminal of one battery to the

negative (-) terminal of the other battery.

4

Connect the red wire from the J15 plug to the positive (+) terminal of the

battery.

5

Connect the black wire from the J15 plug to the negative (-) terminal of the

battery.

6

Turn ON AC power to the operator.

7

Turn ON the AC power switch on the operator.

8

Plug the J15 plug back into the control board.

+

-

-

-

Bridge Rectifier

J15 Plug

Red (+)

Black (-)

Red (+)

Black (-)

33AH Batteries

(with heater)

(without heater)