DIP SWITCH FUNCTIONS

TIMER

RADIO

OSC

TIMER

ON

RADIO

ON

OSC

ON

switch “

” activates the TIMER. See page 21

for details

switch “

” allows the radio receiver to override

the timer. See page 21 for details.

switch “

” allows the radio receiver to top and

reverse the gate n any direction.
signal stops gate,

second signal

gate.

.

s

i

During a cycle the first

a

reverses

FAIL SF/SC

1-PASS

SLAVE

AUTO OPEN

OPEN L/R

This is to set the operator as fail-safe or fail secure.

for

on power failure,

board will monitor battery voltage to make sure gate opens before battery drains out
completely.

for

on power failure gate will run until battery is low and

stay close.

This is a true one pass anti-tailgating feature. This feature may only be used with safety
loops. With this switch in the “

” position, the gate will open until one car passes the

safety loops then it will stop and close. If a second car pulls on the loop the gate will stop
the car must then back off the loop before the gate will close.

This feature is used on master/slave setups. Set slave switch “

” on slave machine, all

other switches “

”. Set slave switch to the “OFF” position on master machine. Set

other function switches on master machine as desired. See page

for more details on

master/slave connections and settings.

This feature is to

open the gate on power interruption. It is a very particular

feature used in areas where the fire department requires the gate to open automatically
after a power outage. Set this dip switch “ON” when this feature is desire.

This feature is to set the direction the operator will open. See page 8 for details.

ON

Fail-safe:

OFF

Fail-secure:

,

ON

ON

OFF

17

automatic

OFF ON

1 2 3 4 5 6 7 8

-----------------------OPEN------------------------

TIMER

RADIO

OSC

FAIL SF/SC

1-PASS

SLAVE

AUTO OPEN

OPEN L/R