Electrical connection, Operators be properly grounded! must, 120 volt electrical plug – Controlled Products Systems Group AOMSW350DC User Manual

Page 15: For power wire enclosure use ul listed conduits, Power switch

background image

14

230V

1

15V

GRD

LINE 1 LINE 2

All gate operators

be properly grounded.

A proper ground in a gate operator installation minimizes or prevents damage from an electrical charge, such as a near
lightning strike or an electrical static discharge.
.
Use a single wire for the ground.

splice two wires for the ground. If the wire breaks or is cut, replace it with a

single length.

use two wires for the ground.

Check with your City code for proper earth ground rod type and proper grounding procedures.

DO NOT

NEVER

MUST

ELECTRICAL CONNECTION

120 Volt

Electrical

Plug.

Power connection | 115VAC | 220VAC Single Phase

LINE 1

LINE 2

ground rod

= 115V N 220V LINE 1

= 115V HOT

220V LINE 2

Connect to

. Use a proper

for a

ground reference.

Use the shortest and thickest wire possible for ground.

ground

GND

For power wire enclosure
use UL listed conduits.

OPERATORS

BE PROPERLY GROUNDED!

MUST

Power switch

For power, a minimum of a

dedicated circuit

breaker is needed.

15-Amp

NOTE:

When applying 230V to

operator make sure voltage
switch is flipped to 230V
position.

NOTE: To use the 120VAC
accessory outlet, connect white
wire from the outlet to neutral.
Only when using 120VAC as the
power source.