beautypg.com

Close delay, Motor run timer, Sensitivity adjustment – Controlled Products Systems Group 3020HX User Manual

Page 15: Warning alarm

background image

15

TO HOlD GaTe Open

Wire switch to stop prior to full open to close reverse switch and press transmitter to restart.

jp-3

Anti-tailgate feature. See Figure #6 on page 11

leD enable SwITCH

The two rows of LED’s, located in the upper left hand corner of the

DGC 3000, Functions for thirty minutes from power-up and turns off

automatically to save power. To verify the LED’s are enabled, activate a limit

switch momentarily. If the corresponding LED does not light, press the

LED enable button, located below the 2 rows of LED’s, to turn on the LED’s

for another 30 minutes.

Safety is for secondary entrapment

– devices connected to this terminal will cause the gate to stop and

reverse 3”. The gate must be activated by a person to move after this has occurred.
Pulse Open/Pulse Close terminal is used to both open and close the gate from a single button. Activation of the

button will open the gate unless the gate is fully open in which case it will close the gate.
24V Power terminal is one leg of 24 VAC power (COMMON is the other side of 24 VAC power, and is

grounded), which can be used to power a radio receiver, digital keypad or other accessory with 24 VAC voltage

requirements.
Important: This terminal must not be grounded at any time even through any controls which will be used to

activate the gate!

fInal aSSeMbly

Operate the gate to the middle of its operation and turn power OFF at the breaker (this prevents activation of

1.

the operator during final assembly). If preferred, you may turn power OFF and back ON at the operator, the

operator will not move until activated.
Remove the arm by removing the stainless steel bolt.

2.

Install the operator cover (make sure the grommet remains properly seated), and re-install the arm as

3.

described under ARM INSTALLATION.
Tighten the stainless steel bolt to 44ft./lbs.

4.

The gate operator installation is not complete unless the warning signs are installed on the gate.

5.