beautypg.com

Mag-lock installation – Controlled Products Systems Group 3020HX User Manual

Page 13

background image

13

CluTCH aDjuSTMenT

Important: Always turn power off before making any adjustment.

Remove the two set screws in the clutch adjuster nut.

1.

Using a 1 ¼” Open-end wrench (available at the factory) tighten the clutch adjuster nut until proper tension

2.

is achieved. (See Note below) Try just a ¼ turn at a time and then test. DO NOT USE A PIPE WRENCH OR

CHANNEL LOCKS TO ADJUST THE CLUTCH!.

Important: Do not over tighten the clutch! Gear damage may result voiding the warranty!
Note:

The clutch must be sufficiently tight so that it does not slip in normal operation and so that the motor

and the current sensor “feel” a load when the gate is obstructed.

After the clutch is properly adjusted, with power OFF, tighten the two set screws in the clutch adjuster nut.

3.

fInal lIMIT aDjuSTMenT

It is possible that a final adjustment may be required for the arm to stop exactly as desired. In the open position,

the swing arms and the pipe arm should be doubled on the top of each other. On CLOSE the motor should

turn off before the arm hits the stop so that it coasts to the stop. If the operation is not as described, adjust the

position of the limit collar to correct the error.

DGC – 2000 COnTROlleR SeTTInGS HanD

This switch changes the direction the motor runs to open the gate, left or right

ClOSe TIMeR

This switch is used to activate (on) or deactivate (off) the automatic close timer. The gate will

close after a specified time as set under Close Delay if this switch is ON unless the gate is

being held open by an accessory.

brake Delay (for slide gates only)

This set of switches determines the length of time between the motor turning off and the

electronic brake coming on. All switches should be ON except for a gate on an incline.

ReveRSe Delay

This set of switches is to prevent instant reversal of the motor to reduce operator/gate stress

and to prevent operator malfunction. Note: Never put all of these switches in the OFF position as

operator damage may result.