ClOSe Delay

If the close time is switched into the circuit, this set of switches adjusts

the length of time the gate stays open before closing automatically. For example,

if you want 45 second you would turn on 32+8+4+1=45 as illustrated below in figure 12.

32

ON

OFF

16 8 4 2 1

Figure 12

MOTOR Run TIMeR

This timer should be set at least 10 seconds or longer than the normal operating time, and

will stop the gate if for some reason the motor runs longer than the switch setting. If this

happens the stop LED will flash 3 times then pause, 3 times then pause, it will continue to

flash until power has been turned off.

SenSITIvITy aDjuSTMenT

This is used to adjust the current level at which the gate will respond to an

obstruction. Turn clock-wise for more sensitive and counter clock-wise for less

sensitive.

Caution:

The current sense feature is designed only to protect the operator and

reduce vehicle damage. It is not intended for pedestrian traffic!

Note:

The setting must always be sensitive enough to respond to an

obstruction, but not so sensitive that it responds without obstruction.

waRnInG alaRM

One to three seconds prior to gate movement.