CTI Products NCB/IM with Internal PSTN Modem User Manual
Page 51

CTI Products, Inc.
NCB/IM User Guide
Appendix F. Specifications
45
A
PPENDIX
F.
S
PECIFICATIONS
NCB/IM Unit
Power:
10 to 30 VDC, Negative Ground, Externally Current Limited
5 watts max. without SMX transceiver
10 watts max. with SMX power line transceiver
North American and International Power Supplies available
Size:
7.5" D x 5.6" W x 1.6" H
Mounting:
Desktop with integral non-slip feet
Wall mount or 19" rack mount with optional adapters
Temperature:
0-60
C
Humidity:
10-95% non-condensing
Listings:
UL1459, CSA C22.2, EC EN60950
Telco Approvals
FCC Part 68 (U.S.), IC CS02 & CS03 (Canada),
BABT NTR2 & NTR3 (UK)
EMI:
Complies with: FCC part 15
Class A
Industry Canada (IC)
Class A
EN55022 (European Union)
Class A
EMC:
Complies with EN50082-1 (European Union)
European:
Carries the CE Mark
Modem:
Internal V.32 turbo 19.2 Kbps, 2 wire dial-up, 2/4 wire leased line
Simultaneous Voice plus Data.
Transceivers Supported:
FTT-10A, TPT/XF-78, TPT/XF-1250, SMX, RS485, PLT22
Maximum packet size:
66 bytes (factory default router configuration)
255 bytes (maximum with software re-configuration)
Dialing:
Modem Controller and Telephone Directory
SNVTs or Explicit messages
Configuration:
Router set as a repeater by factory default.
Bridge, Configured, or Learning type set using standard L
ON
W
ORKS
network management tools capable of configuring routers.
LNS plug-in provided for configuration of telephone parameters.
Installation:
Can be done with Standard Network Tools