Remote scroll up, Remote scroll down – CONTREX CX-1010 User Manual
Page 22

Page 20
Remote Scroll Up
(J7 pins 8, 9)
Digital Input 14
REMOTE SCROLL UP is a maintained input. When it is
closed, any Control Parameter that you enter into the
Remote Scroll Parameter (CP-300) can be incremented
at the Remote Scroll Rate (CP-301). As a maintained
input, REMOTE SCROLL UP is only active when the
operator device is closed.
Remote Scroll Down
(J7 pins 8,10)
Digital Input 15
REMOTE SCROLL DOWN is a maintained input. When
it is closed, any Control Parameter that you enter into
the Remote Scroll Parameter (CP-300) can be
decremented at the Remote Scroll Rate (CP-301). As a
maintained input, REMOTE SCROLL DOWN is only
active when the operator device is closed.
Figure 26 Remote Scroll Up
REMOTE SCROLL
UP
8
9
J7
COM
DI_14
Figure 27 Remote Scroll Down
REMOTE SCROLL
DOWN
8
10
J7
COM
DI_15