◎ Before connecting sensors, check driving voltage and output signal type of the sensor.

Since output signal types of the sensors are divided into Open Collector and Voltage

Output type in general, the cabling must be done properly after considering these

typed.

◎ If you want to use Alarm Input, the types of sensor must be selected in OSD menu

. The sensor types are Normal Open and Normal. If sensor type is not selected properly,

the alarm can be activated reversely.

◎ Maximum allowable electrical load of relay is shown bellow table.

Relay Output

Sensor Input

Signal

Description

COM+

Connect (+) cable of electric power sources for Sensors to this port
as shown in the circuit above.

IN1-, IN2-,
IN3- , IN4-

Connect output of sensors for each port as shown in the circuit
above.

Normal Open

Output Voltage is high state when sensor is activated

Normal Close

Output Voltage is high state when sensor is not activated

Driving Power

DC

110V AC

Max. Load

24V DC, 1A

125V AC, 0.5A

LOAD

AC or DC

Internal Circuit

OUT 1

Internal Circuit

+

-

+

-

IN 1-

IN 4-

Sensor Output 1

Sensor Output 4

IN COM+

+5V ~ 12V

16

17