Relay output sensor input – CNB PM1063P User Manual
Page 9
◎ Before connecting sensors, check driving voltage and output signal type of the sensor.
Since output signal types of the sensors are divided into Open Collector and Voltage
Output type in general, the cabling must be done properly after considering these
typed.
◎ If you want to use Alarm Input, the types of sensor must be selected in OSD menu
. The sensor types are Normal Open and Normal. If sensor type is not selected properly,
the alarm can be activated reversely.
◎ Maximum allowable electrical load of relay is shown bellow table.
Relay Output
Sensor Input
Signal
Description
COM+
Connect (+) cable of electric power sources for Sensors to this port
as shown in the circuit above.
IN1-, IN2-,
IN3- , IN4-
Connect output of sensors for each port as shown in the circuit
above.
Normal Open
Output Voltage is high state when sensor is activated
Normal Close
Output Voltage is high state when sensor is not activated
Driving Power
DC
110V AC
Max. Load
24V DC, 1A
125V AC, 0.5A
LOAD
AC or DC
Internal Circuit
OUT 1
Internal Circuit
+
-
+
-
IN 1-
IN 4-
Sensor Output 1
Sensor Output 4
IN COM+
+5V ~ 12V
16
17