◎ Termination switch(Pin 4) is used in cases listed below.
◎ Long-distance communication between the controller and the camera (1-to-1
connection)
- When the connecting distance between the two units is especially long,
communication errors may occur due to the impedance of transmission cable. In this
case, set the termination switch of both units to ON.
◎ Controlling multiple cameras (Multiple connection)
- The camera may not operate correctly if multiple cameras are connected and
controlled. In this case, set the termination switch of the controller and the last
connected camera to ON and the switch of other cameras is OFF.
◎ Select the appropriate Protocol with DIP switch combination.
◎ If you want to control using DVR or P/T controller, their protocol must be identical to
camera. Otherwise, you can not control the camera.
◎ If you changed camera protocol by changing DIP S/W, the change will be effective
after you reboot the camera.
◎ Factory default of protocol is “PELCO-D, 2400 bps”.
Communication Protocol Setup
Termination Switch Setting
Termination Switch is used in case listed below.
NO
PROTOCOL
BUADRATE
#1
#2
#3
0
PELCO-D
2400bps
OFF
OFF
OFF
1
PELCO-D
9600bps
ON
OFF
OFF
2
PELCO-P
4800bps
OFF
ON
OFF
3
PELCO-P
9600bps
ON
ON
OFF
Others
Reserved
10
11
ON
1
2
3
4
ON
1
2
3
4
+
-
RS-485
#1
#2
#n
Termination Switch OFF Termination Switch OFF
Termination Switch ON
Termination Switch ON
Keyboard Controller/DVR