Bâàwééü fñxxw wéåx fxü|xб |с@åçxà, Installation, Dip switch setup – CNB ISS2965PW User Manual
Page 9
bâàwÉÉÜ fÑxxw WÉÅx fxÜ|xб |С@åÇxà
9
2. Installation
⊙
DIP Switch Setup
■ Before installing the camera, you should set the DIP switches to configure the camera ID, communication protocol. Do not use the system upgrade
terminal.
■ Input Sensor Active Type
• When a sensor input is used, its functional type should be set.
There are two types; Normal Open type and Normal Close type.
-Normal Open : Voltage is let out when the sensor is activated
-Normal Close : Voltage is let out when the sensor is not activated
Pin
Switch position
Sensor type
ST1 (Pin 4)
ON
Sensor 1 Normal Close
OFF
Sensor 1 Normal Open
ST2 (Pin 5)
ON
Sensor 2 Normal Close
OFF
Sensor 2 Normal Open
ST3 (Pin 6)
ON
Sensor 3 Normal Close
OFF
Sensor 3 Normal Open
ST4 (Pin 7)
ON
Sensor 4 Normal Close
OFF
Sensor 4 Normal Open
• If a wrong type of sensor is selected, it activates in the opposite way to the sensor input.