Creating an insteon scene, Advanced features, Restoring power to 240v load controller – INSTEON Load Controller 220V / 240V 30 Amp, N/O and N/C (2477SA1, 2477SA2) Manual User Manual
Page 9

240V Load Controller Owner’s Manual
Page 9 of 14
CREATING AN INSTEON SCENE
INSTEON scenes let you activate dramatic lighting moods with the press of just one button. For example,
you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with
the tap of a button on a controller.
INSTEON scenes are very easy to set up – just link more than one responder to the same On/Off or
Scene button on a controller. Then, when you press any of the linked buttons on the controller, all of the
INSTEON devices linked in the scene will respond as a group.
ADVANCED FEATURES
Restoring Power to 240V Load Controller
240V Load Controller stores all of its settings, such as links to other INSTEON devices, with non-volatile
memory. Because settings are saved in this non-volatile memory, they will not be lost in the event of a
power failure.
Resetting 240V Load Controller to its Factory Default Settings
The factory reset procedure will clear 240V Load Controller of all INSTEON links and programmed X10
addresses.
NOTE: Depending on the location of your circuit breaker or fuse panel, you might need to recruit
someone to help you perform the following procedure.
1) If you are using a controller to control 240V Load Controller, be sure to unlink it from the controller.
See Unlinking 240V Load Controller from an INSTEON Controller.
2) If you are using 240V Load Controller to control any INSTEON devices, unlink those devices from
240V Load Controller. See Unlinking an INSTEON Responder from 240V Load Controller.
3) At the circuit breaker or fuse panel, disable the circuit supplying power to the junction box for about
10 seconds
4) While holding down the Set button on 240V Load Controller, re-enable power to the junction box from
the circuit breaker or fuse panel, making sure not to let go of the Set button
240V Load Controller
will
beep
5) Continue to hold down the Set button for 3 seconds and then release
A few seconds after you release the button, 240V Load Controller
will
double-beep and its Status
LED
will
turn on solid green
The load
will
turn on