CONTROLLING INSTEON RESPONDERS FROM 240V LOAD
CONTROLLER
Linking 240V Load Controller to an INSTEON Responder
To use 240V Load Controller as an INSTEON controller, follow these steps to link 240V Load Controller and an
INSTEON responder (the device you wish to control with 240V Load Controller) together. Refer to the
responder’s Owner’s Manual for detailed instructions on how to properly install and link it to 240V Load
Controller.
The following will work for the most common INSTEON devices:
1) At the responder, set it to the state you wish to be activated from 240V Load Controller (turn it on if you
wish it to be on, or off if you wish it to be off when 240V Load Controller activates the scene, set On-Levels,
etc.)
• If the responder is a multi-scene device (e.g., KeypadLinc), tap the Scene button you wish to
control until its LED illuminates
2) Set 240V Load Controller to linking mode by pressing and holding the Set button until it beeps (3 seconds)
The 240V Load Controller Status LED will begin blinking green
You will have 4 minutes to complete the next step before linking mode automatically times out.
3) Press and hold the responder’s Set button for 3 seconds
240V Load Controller will double-beep and its Status LED will turn on solid green if the load is on or
solid red if it is off
4) Confirm that linking was successful by tapping the Set button on 240V Load Controller on and then off
The responder will respond appropriately
5) If you wish to link multiple responders to the same 240V Load Controller, repeat steps 1-4 with each
responder
Unlinking an INSTEON Responder from 240V Load Controller
If you are no longer going to use an INSTEON responder that has previously been linked to 240V Load
Controller, it is very important that you unlink it. Otherwise, 240V Load Controller will retry any commands
repetitively, thus slowing down the system.
The following will work on the most common INSTEON devices:
1) If the responder is a multi-scene device, tap the Scene button you wish to remove control from until its LED
illuminates
2) Set 240V Load Controller to linking mode by pressing and holding the Set button until it beeps (3 seconds)
The 240V Load Controller Status LED will begin blinking green
3) Set 240V Load Controller to unlinking mode by pressing and holding the Set button until it beeps again (3
seconds)
The 240V Load Controller Status LED will begin blinking red
You will have 4 minutes to complete the next step before unlinking mode automatically times out.
4) Press and hold the responder’s Set button for 3 seconds
240V Load Controller will double-beep and its Status LED will turn on solid green if the load is on or
solid red if it is off
5) Confirm that unlinking was successful by tapping the Set button on 240V Load Controller on and then off
The responder will no longer respond