beautypg.com

INSTEON Load Controller 220V / 240V 30 Amp, N/O and N/C (2477SA1, 2477SA2) Manual User Manual

Page 7

background image

240V Load Controller Owner’s Manual


Page 7 of 14

CONTROLLING 240V LOAD CONTROLLER FROM AN INSTEON
CONTROLLER

Linking an INSTEON Controller to 240V Load Controller

To use 240V Load Controller as a responder to an INSTEON controller, follow these steps to link 240V
Load Controller and the controller together. Refer to the controller’s Owner’s Manual for detailed
instructions on how to properly install and link it to 240V Load Controller.

The following will work for the most common INSTEON devices:

1)

Use the Set button on 240V Load Controller to set the load to the state you wish to activate from the
controller (turn it on if you wish it to be on or off if you wish it to be off when the controller activates
the scene)

2)

Set the controller to linking mode. (For most controllers, press and hold an On or Scene button for 10
seconds or the Set button for 3 seconds.)

You will have 4 minutes to complete the next step before linking mode automatically times out.

3)

Press and hold the Set button on 240V Load Controller until it double-beeps (3 seconds)

The 240V Load Controller Status LED

will

flash once and then turn on solid green if the load is on

or solid red if it is off

4)

Confirm that linking was successful by tapping the button you just linked to on the controller

240V Load Controller

will

respond appropriately

Unlinking 240V Load Controller from an INSTEON Controller

If you are going to discontinue using 240V Load Controller, it is very important that you unlink it from any
linked controllers. Otherwise, the controller will retry any commands repetitively, thus slowing down the
system.

The following will work for the most common INSTEON devices:

1) Set the controller to unlinking mode. (For most controllers, press and hold an On or Scene button for

10 seconds twice or the Set button for 3 seconds twice.)

You will have 4 minutes to complete the next step before unlinking mode automatically times out.

2) Press and hold the Set button on 240V Load Controller until it double-beeps (3 seconds)

The 240V Load Controller Status LED

will

flash once and then turn on solid green if the load is on

or solid red if it is off

3) Confirm that unlinking was successful by tapping the button you just unlinked from on the controller

240V Load Controller

will

no longer respond