The controller can
turn off Dimmer
Module, but Dimmer
Module does not turn
on when I send an on
command from the
controller
Dimmer Module may be
added to a scene at its off
state
Re-add Dimmer Module to a scene as a controller
while the load is on. See
The load is buzzing
when on or dim
The dimming component
inside Dimmer Module
“chops” the powerline sine
wave to reduce the power
The bulb filaments are vibrating. Use rough-service,
130 Volt, or appliance-grade bulbs to reduce the
noise
Run Dimmer Module in the full-on mode or switch to
an On/Off Module
The load only turns
off when I tap a
button on the
controller but I can
brighten or dim it
The on-level may be set to
very dim or full-off
Re-add Dimmer Module to the controller at a brighter
on-level. See
Make Dimmer Module a Responder
Dimmer Module is
locked up
A surge or excessive
noise on the powerline
may have locked it up
Unplug Dimmer Module for 10 seconds and then
reinstall
If the above doesn’t work, perform a factory reset.
See
The lamp does not
turn on when I
manually activate the
lamp’s switch
Dimmer Module may be
off
Turn on Dimmer Module using the paddle on the
side of the module
Bulb may be burnt out
Replace the lamp’s bulb
The load is not being
controlled by Dimmer
Module
The load may not be
getting power
Make sure the load’s built-in switch is in the on
position