Local on-level, Air gap, Beep on button press – INSTEON Keypad Dimmer (Dual-Band) (2334-2xx US) Manual User Manual
Page 16: Error blink, Changing to 6-button or 8-button plate
Page 16 of 24 Rev: 7/25/2013 9:16 AM
Local On-Level
The local on-level is the default brightness level at which the light(s) physically wired to Keypad will turn on. The
default local on-level is 100%, but can be set to any one of 33 settings, 32 fixed brightness levels (3% to 100%) or
“Resume Bright,” which will result in the light returning to the brightness level it was at prior to being turned off.
We recommend using home-management software such as HouseLinc to set the local on-level. However, you can
also change it manually by following the steps below.
1) Press and hold On and/or Off (or Main in 8-button configuration) until the connected light is at the brightness desired
when turned on locally (turn the light off if you wish to use the “Resume Bright” feature)
2) Tap the Set button
Keypad will beep
3) Test the Local On-Level settings by tapping the On/Off or Main buttons
Air Gap
To remove all power from Keypad and connected light(s), pull out the Set button at the bottom of the switch as far
as it will go, about 1/8”. (It might be helpful to use a small screwdriver.) This will open the mechanical contacts and
create an air gap.
To restore power, press the air gap back into place until its top is even with the trim frame.
Beep on Button Press
Default = Off
This setting is adjustable via software or a central controller only.
Error Blink
Default = on
This setting is adjustable via software or a central controller only. Keypad Dimmer LED blinks red for a few seconds
if one or more responders do not acknowledge a message.
Changing to 6-Button or 8-Button Plate
-
The 6-button plate provides a dedicated load ON button at the top of the switch, a dedicated load OFF button
at the bottom, and four programmable secondary buttons between the On and Off buttons
-
The 8-button plate provides a dedicated load MAIN On/Off button in the top left-most position of the keypad
and seven programmable secondary buttons.
Attach the change-out plate to the switch body by aligning the tabs. Snap into place.