background image

Chapter 3. Operation

61200054L2-1

Nx56/64 (EIA-530) Option Module User Manual

3-7

8)0 INHIB

The Nx interface detects an uninterrupted string of 0s
being transmitted toward the network. If

0

S

are transmit-

ted for more than one second, the TSU 100 forces

1

S

towards the network.
Choices: On or Off

Table 3-1 shows the conditions which cause the port con-
trol signal to be deactivated.

3)FACTORY RESTORE, Submenu of 3)UTIL

This selection is used to restore the factory default set-
tings for all pass through option module parameters.

Operation

To return the unit to the opening main menu with all the
factory default settings restored, do the following:

1.

Follow the standard operating procedure to access
the

3)UTIL

menu items.

2.

With the cursor on

3)FACT RESTORE

, press

Enter

.

Table 3-1. Normal Mode Operation

SIGNAL

RTS

V.54

LOOPBACK

511 TEST

ON

SELF-TEST

ACTIVE

NETWORK

TEST ACTIVE

NO DS0

MAPPED

NETWORK

ALARM

CTS

Follows

Off

Off

Off

Off

Off

Off

DCD

-

-

-

Off

-

Off

Off

DSR

-

Off

Off

Off

Off

Off

-

- = Do not care

Force On = On under all conditions