beautypg.com

Ws200 registration – Clear-Com HME DX200 User Manual

Page 3

background image

3

WS200 Registration

The first time you operate the WS200, you must register it for use with a specific DX100 or DX200 Base Station.
The base station will then recognize the WS200 when its power is on, and will be able to tell the difference between
it and other electronic equipment operating on similar frequencies, or DX family Beltpacs or All-in-one Headsets.

NOTE:

The WS200 must be within 6 feet (1.83 meters) of the base station while being registered.

Registration Procedure:

Be sure the WS200 is turned off and the base station power is on.
On the base station, press and release the REG/REGISTER BELTPAC button.

⎯ The REGISTRATION STATUS display will show a small “o” for open.

On the WS200, press and hold the ISO button while you press and release the PWR/POWER button to turn the

unit on, and then release the ISO button. This will cause the WS200 to enter the registration mode.

⎯ The REGISTRATION STATUS display on the base station will continue to show a small “o.”

⎯ The ISO and IC lights on the WS200 will be blinking red then will change to a steady green IC light.

When registration is successfully completed:

If you have a headset plugged into the WS200 or if the speaker is on, you will hear a voice message in the

headset or speaker saying “Power on, Speaker, Version #, Begin registration, Registration complete…”

The REGISTRATION STATUS display on the base station will show the ID number assigned to the

WS200, for about 10 seconds.

NOTE:

ID numbers are assigned sequentially to registered Beltpacs, All-in-one Headsets and Speaker
Stations as 0 thru 9, A, b, C, d and E (up to 15 total).

The IC light on the WS200 will remain on steady green.

Registration buttons and indicators on MB100 and BS200 Base Stations

This manual is related to the following products: