Safety devices

RX

TX

Confi gure either (N.C.) contacts CX or CY, input for
safety devices such as photocells, that comply with EN
12978 standards. See CX or CY input functions in:

- C1 «re-open during closing phase», When the
gate leaf is closing, opening the contact triggers the
inversion of the direction of movement until the gate
leaf is fully open.

- C2 «re-close during opening phase», When gate
is opening, if the contact is opened it triggers an
inversion of the direction until gate is fully closed;

- C3 «partial stop», gate stops if moving and
automatically shuts (if this functions has been
selected);

- C4 «stand-by Obstacle», Halts the moving gate
leaves causing them to start moving again once
obstacle is removed.

- Deactivated, if the contact is unused.

DIR photocells

RX

TX

./ # .#

DOC photocells

DF

# ./ .#

6

6

.#

./

#

6

# ./ .#

Confi gure either (N.C.) contacts C7 or C8, input
for EN 12978 compliant safety devices such as
sensitive edges. See C7 or C8 input functions in:

- C7 «re-open during closing phase», - During
gate closing, opening the contact causes
inversion of movement until gate is fully open;

- C8 «re-close during opening phase», - During
gate opening, opening the contact causes
inversion of movement until gate is fully close;

OFF, is the contact is unused

DF with DFI con-
nections monitor
card