Installation and wiring – Burkert Type 8045 User Manual
Page 11
11
Installation and wiring
Type 8045
6.6.
electrical connection
Type of connection
Through two M20x1,5 cable
glands
Cable specifications
• cable type
• Cross section
• Diameter of each cable:
- if only one cable is used
per cable gland
- if two cables are used per
cable gland
• shielded
• 0,5 to 1,5 mm
2
- 6...12 mm
- 4 mm, with the supplied
multi-way seal
7.
insTAllATion AnD WirinG
7.1.
safety instructions
danger
risk of injury due to high pressure in the installation.
risk of injury due to electrical voltage.
risk of injury due to high fluid temperatures.
risk of injury due to the nature of the fluid.
Warning
risk of injury due to non-conforming installation.
• The electrical and fluid installation can only be carried out by
qualified and skilled staff with the appropriate tools.
• Install appropriate safety systems (correctly rated fuse and/or
circuit-breaker);
• Respect standard NF C 15-100 / IEC 60364.
• Respect the assembly instructions for the fitting used.
risk of injury due to unintentional switch on of power supply
or uncontrolled restarting of the installation.
• Take appropriate measures to avoid unintentional activation of
the installation.
• Guarantee a set or controlled restarting of the process subse-
quent to any intervention on the device.
English