8
note
the fitting may be damaged by the fluid in contact
with.
• Systematically check the chemical compatibility of the
component materials of the fitting and the fluids likely
to come into contact with it (for example: alcohols,
strong or concentrated acids, aldehydes, alkaline
compounds, esters, aliphatic compounds, ketones,
halogenated aromatics or hydrocarbons, oxidants and
chlorinated agents).
English
9
4. GenerAl informATion
To contact the manufacturer of the device use following
address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL
The addresses of our international branches can be found
on the Internet at:
www.burkert.com
Warranty conditions
The condition governing the legal warranty is the conforming
use of the S039 in observance of the operating conditions
specified in this manual.
information on the internet
You can find the user manuals and technical data sheets
regarding the type S039 at:
www.burkert.com
English
9
10
5. deScripTion
The S039 fitting is intended to measure the flow rate of clean
fluids in DN6 to DN50 pipes thanks to its paddle-wheel. Its
combination with an SE39 electronic module builds an 8039
threshold detector.
The fluid flowing in the piping makes the paddle-wheel turn.
The paddle-wheel rotational frequency f is proportional to
the flow rate.
The electronic device can be removed without opening the
piping or stopping the process.
Order codes of the fittings S039:
DN Connections
Order code
06 External
threads
G 1/4''
552558
G 1/2''
552525
metric, 16 x 1,5
552414
08 External
threads
G 1/2''
444670
NPT 1/2''
444671
15 Internal
threads
G 1/2''
440645
NPT 1/2''
444672
20 Internal
threads
G 3/4''
440646
NPT 3/4''
444673
25 Internal
threads
G 1''
440647
NPT 1''
444674
English
11
32 Internal
threads
G 1 1/4''
440648
NPT 1 1/4''
444675
40 Internal
threads
G 1 1/2''
440649
NPT 1 1/2''
444676
50 Internal
threads
G 2''
440650
NPT 2''
444677
6. TechnicAl dATA
conditions of use
The fluid temperatures and pressures may be
restricted by the electronic device mounted on the
fitting: refer to the relevant manual.
Ambient temperature Depends on the associated electronic
module. Refer to the instruction manual
of the 8039.
Pressure class
PN10; The fluid pressure may be
restrictec by the fluid temperature,
see Fig. 1.
Fluid temperature
-15 °C to +100 °C
English