Burkert Type 8076 User Manual
Page 20

20
Installation and wiring
Type 8026- 8036- 8076
7.2.2. recommendations on installing an
8076 on a pipe
→
Install the fitting S070 on the pipe in such a way that the oval
gear axes are in the horizontal plane, as shown in „Fig. 15“.
Correct
Incorrect
Fig. 15: The oval gear axes must be horizontal (seen from the front)
→
Fit the display module (see related operating manual) to para-
meter the device.
→
Assemble flowmeter type 8076 (see „Fig. 13“)
→
Set the K factor parameter (see chap. „8.8.8“) or have it deter-
mined through a teach-in procedure.
7.3.
Wiring
danger
risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source before
carrying out work on the system.
• Observe all applicable accident protection and safety regula-
tions for electrical equipment.
• Use a high quality electrical power supply (filtered and
regulated).
• Make sure the installation is equipotential. See chap.
• Use a shielded cable.
• Once the device is wired, set the "HWMode" parameter
depending on the wiring carried out, sink/NPN or source/
PNP. See chap. „8.8.3“.
English