12 - 8623-2 Standard
english
Type 8020 flow rate sensor with
Hall-Sensor
Example of connection: flow rate sensor with Hall sensor
(type 8020)
Fig.: Connection of the flow rate sensor type 8020 with Hall sensor
Type 8623-2 flow controller
3
1
M8 (3-pole)
1 (brown)
4
3 (blue)
4 (black)
NOTE
For connection of flow rate sensor type 8020 with Hall sensor
to controller type 8623-2, a supply voltage is required (pin 1)!
Connection to 8020 (Hall sensor)
8020 (pin 1)
8623-2 (M8, pin 1 24 V DC output)
8020 (pin 2)
8623-2 (M8, pin 4 frequency input)
8020 (pin 3)
8623-2 (M8, pin 3 GND)
NOTE
For connection of flow rate sensor type 8020 with coil to
controller type 8623-2, no supply voltage is required!
Connection to 8020 (coil):
8020 (pin 2)
8623-2 (M8, pin 4 frequency input)
8020 (pin 3)
8623-2 (M8, pin 3 GND)
- Type 1062 (112 pages)
- Type 1050 (4 pages)
- Type 8750 (64 pages)
- Type 8750 (82 pages)
- Type 8681 (40 pages)
- Type 8681 (90 pages)
- Type 8798 (2 pages)
- Type 8791 (4 pages)
- Type 8798 (106 pages)
- Type 8718 (34 pages)
- Type 8792 (118 pages)
- Type 8791 (15 pages)
- Type 8792 (136 pages)
- Type 8792 (252 pages)
- Type 8791 (21 pages)
- Type 8791 (154 pages)
- Type 8791 (106 pages)
- Type 8791 (184 pages)
- Type 8791 (28 pages)
- Type 0911 (76 pages)
- Type 0911 (46 pages)
- Type 0911 (64 pages)
- Type 0911 (84 pages)
- Type 1058 (31 pages)
- Type 1060 (4 pages)
- Type 1066 (112 pages)
- Type 1067 (158 pages)
- Type 1077-2 (33 pages)
- Type 1094 (12 pages)
- Type 1094 (41 pages)
- Type 1094 (82 pages)
- Type 1094 (126 pages)
- Type 1115 (25 pages)
- Type 1150 (99 pages)
- Type 1541 (2 pages)
- Type 5142 (6 pages)
- Type 8619 (40 pages)
- Type 8619 (134 pages)
- Type 8620 (177 pages)
- Type 8622 (4 pages)
- Type 8623 (90 pages)
- Type 8625 (118 pages)
- Type 8624 (124 pages)
- Type 8718 (254 pages)