Technical data of the valve block – Burkert Type 8644 User Manual
Page 28
24 - 8644/Rockwell
S
YSTEM
D
ESCRIPTION
Technical data of the valve block
ATTENTION!
Observe current consumption of the modules!
On project planning of an AirLINE station, observe the current consumption of the logic of
each participant! This is given in each module-specific data sheet. It may differ from
module to module. Hence the number of possible participants that can be connected
depends on the specific construction of the station.
M
ount
in
g
di
mension
1
1 mm
16.5
mm
V
a
lve oper
a
tion
C/D
(3
/2
-w
a
y
)
L/N
(5
/3
-w
a
y
)
2xC
(2
x 3
/2-
w
a
y)
C/D
(3
/2
-w
a
y
)
T
y
pe 6
526
L/
N
(5
/3
-w
a
y
)
T
y
pe 6
524
T
y
pe 0
460*
**
T
y
pe 6
524
T
y
p
e 046
1**
*
H
(5
/2
-w
a
y
)
H
(
5/2
-p
uls
ed)
H
(5
/2
-w
a
y
)
T
y
pe 6
527
H
(
5
/2
-pul
se
d)
T
y
pe 6
525
T
y
pe 0
460
T
y
p
e 046
1
Flo
w
300
I/m
in
20
0 I/m
in
300 I
/m
in
700
I/m
in
5
00 I/
mi
n
Pr
essur
e ra
n
g
e
(w
it
h P
sh
ut-
o
ff
)
2.5 .
..
7
bar
5 .
..
7 b
a
r
2.
5 ..
. 7 ba
r
-
2.5 .
..
7
bar
-
2 ..
. 10 b
a
r
-
2.5 .
..
7
bar
-
Po
w
e
r
1 W
0,
9
W
2 x 1
W
wi
th po
wer
r
educ
ti
on
1 W
2
W
0
.9 W
C
u
rr
en
t b
e
fo
re
/
aft
e
r
po
we
r r
e
du
c
tion
43/2
8 mA
41
/-
mA
2 x
43/1
8 mA
4
2
/33
m
A
85
/5
2 m
A
4
1
/-
mA
V
a
lve plac
es (
m
ax
.)
6
4
26
32
32
24
Ele
c
tr
ical m
o
dule
2-
fo
ld,
8-
fo
ld
2-
fo
ld
bis
ta
b
le
l
2-
fold 2
x
m
onos
ta
b
le
8
-f
o
ld 2x
m
onos
tab
le
2
-fo
ld
, 3
-fo
ld
*,
4
-fo
ld
2
-fo
ld
b
is
ta
b
le
Pneumat
ic modu
le
2-
fo
ld,
8-
fo
ld
2-
fo
ld
bis
ta
b
le
2-
fold 2
x
m
onos
ta
b
le
8
-f
o
ld 2x
m
onos
tab
le
2
-fo
ld
, 3
-fo
ld
*,
4
-fo
ld
2
-fo
ld
b
is
ta
b
le
Pr
ot
ect
ion c
lass
(i
n te
rm
in
al m
odel
)
IP
2
0
Ambient
t
e
mper
at
ure
0 .
..
+5
5
o
C
0 .
..
+
50
o
C
0
...
+
5
5
o
C
0
..
. +
55
o
C
0 .
..
+
50
o
C
St
or
a
g
e t
e
mper
at
ure
-2
0 ...
+6
0
o
C
No
mi
nal oper
a
ting
mode
Con
tinuous
ope
rati
on (
100
% ED)
O
p
e
rat
in
g v
o
lt
a
g
e*
24 V
/ DC;
-
15
% / +
20 % t
oler
anc
e**
;r
es
id
ual r
ippl
e at f
iel
d b
u
s i
nter
fac
e 5 %
Pr
ot
ect
ion c
lass
3 ac
co
rd
ing
to VDE
058
0
T
o
ta
l curr
ent
Depe
nden
t on t
he c
onne
ct
ion t
ec
hnol
ogy
, the
e
x
pan
si
on s
tag
e and t
he c
ont
rol.
*
3 x 10 mm valves for istallation dimension 16.5 mm
**
max. +10 % for the EEx-n-version
***
The following limitations apply to the voltage supply tolerances for the system as a whole
(see:
T
echnical Data of the System):
V
alv
e types 0460, 0461:
±10 % f
or the EEx n-v
ersion
of this type: +10 %