NOTE

Under normal conditions, the devices work maintenance-free.

Drives:

- Piezo drive,

Valve housing with membrane and seat seals (5/2)

Service ports 2 (B) / 4 (A) with change-over plate to MAMUR flange layout,
plus feed and drain connections 1, 3 and 5 with G 1/4 internal thread

Can be installed in any position, preferably with connection at top

Operating voltage:

24 V DC ±10%

Pressure range:

2,5 to 7 bar

Flange:

NAMUR flange

Standby current:

< 150 µA at 24 V

Power dissipation:

< 10 mW

Permissible temperature range

Ambient:

- 20 to +55 ° C

Medium:

- 20 to +50 ° C

Protection class:

IP 65

The valve can be supplied in explosion protection class
to EN 50020, II 2G EEx ia IIC T6