English, 5 faults – Burkert Type 6520 User Manual
Page 11
6520 - 9
english
Check the electrical
connetctions
Ensure the operating voltage is
as given on the rating plate
Implement the pressure supply
with as large a volume as pos-
sible (even for pilot devices
such as pressure regulators,
service units, shut-off valves,
etc.);
minimum operating pressure
≥≥≥≥≥ 2,5 bar,
minimum flow rate 270 l/min
at P connection of valve
1)
Implement the pressure supply
with as large a volume as pos-
sible (even for pilot devices
such as pressure regulators,
service units, shut -off valves,
etc.);
minimum operating pressure
≥≥≥≥≥ 2,5 bar,
minimum flow rate 270 l/min
at P connection of valve
1)
Use silencers or expansion
vessels with correspondingly-
large dimensions.
Clean soiled silencers.
Pressure load the exhaust
channels with pressure pulse to
blow away the dirt; Install a
new pilot or main valve if this
measure is unsuccessful.
5 FAULTS
Insufficient or no
operating voltage;
Pressure supply insuffi-
cient or not present.
Pressure supply insuffi-
cient or not present;
Insufficient venting of
the exhaust channels
due to a silencer that is
soiled or is too small
(back pressure);
Soiling or foreign bodies
in the pilot or main valve.
Valve does not
switch:
Valves switches
delayed or
blows out from
the bleed ports:
1)
In the case of version with reduced flow rate
(ID no. 141 721 Z; ID no. 141 72 S), the flow rate is reduced to 150 l/min.
Remedy
Possible cause
Fault