beautypg.com

Use in potentially explosive areas of gas, Rating plate, Electrical data – Burkert Type 6013 User Manual

Page 9: English

background image

9

Technical data

6.4.1. Rating plate

Designation Ex-protection

Identnumber, production date

Serial number

Technical data (see chapter 6.5 and 6.6)

Drawing-No. of coil

Designation IECEx-protection

MADE

IN

GERMANY

II 2G

Ex ia IIC T6 Gb

II 2D

Ex ia IIIC T80°C Db

AC10-Z3-6-PD94 IP54

P,U,I,Tamb s.manual

S/N

999999 W24LA

Fig. 2: Description of the rating plate

6.5.

Use in potentially explosive
areas of gas

The device may be used either in the hazardous area of gas
or dust but not in a hybrid mixture.

6.5.1. Electrical data

Electrical data for ignition protection type Ex “ia” and gas group II C:

Coil
size

L x W x H

[mm]

Mass

[g]

Encoding

Structure

Temp.

class

5

45 x 32 x 41

160

PD89

Diodes in the
coil

T6

PE28

T5

78 x 32 x 41

220

PD93

Diodes in the
device socket

T6

PE29

T5

6

50 x 40 x 41

210

PD94

Diodes in the
coil

T6

PE30

T5

83 x 40 x 41

270

PD95

Diodes in the
device socket

T6

PE31

T5

english

PTB 01 ATEX 2101