Dismantling the module, Mounting the valve block, English i – Burkert Type 5470 User Manual
Page 15: English, Standard rails, Wall mounting

5470 / MP05 - 13
english
I
NSTALLATION
, I
NITIALISATION
AND
S
ERVICE
english
Dismantling the module
Unlatch the upper locking hook by using a screwdriver on the end dismantling-groove.
Remove the block part / module sideways.
Other possible uses of the connecting module, - right-hand -
• As a separation module for special applications when building up several pressure levels in a single
block.
• Additional supply lines for larger valve blocks.
Mounting the valve block
Standard rails
NOTE
Where necessary, break out the rated break-points of ports 1 and 3.
Installation
Hang the valve block onto the upper
groove of the standard rail.
Latch the lower clamp into the standard
rail.
Firmly tighten the screws on the clamp.
Dismounting
Loosen the clamping screws (by about
4 revolutions).
Remove the block upwards from the
standard rail.
Figure 2: Mounting the valve block
Connecting
module
Standard rail 35 x 15
or 35 x 7,5
EN 50022
Wall mounting
Electrical connection
can be rotated by 180 °
Wall mounting
Fix the module system directly to the wall using M4 screws.