Electrical connections
Pilot valve Type 6106
• Read the voltage, electrical power, type of protection and current from the rating plate!
• Voltage tolerance ±10 %;
• Ensure a long service life of the pilot valve by using a 10µ filter!
• Electrical connection: Instrument socket type 2506 to the tag connection on the coil (tigthening torque:
1 Nm);
• Proctection level IP 65 (only in combination with appliance socket type 2506);
• To match the cable run, the instrument socket can be mounted rotated by 180°.
NOTE
The coil heats up during opeation!
ATTENTION!
Media
• Filtered compressed air (max. particle size 10 µm), preferably non-oiled
• Operation is possible with oiled air
• Seal material:
NBR
• Perissible medium temperature:
max. + 50 ° C
• Perissible ambient temperature:
max. + 55 ° C
• Operational pressure range:
2 - 8 bar
ATTENTION!
NOTE
The pilot pressure of the pneumatic controller is dependent on the pressure of the flow
of medium: it must not exceed a maximum of 8 bar!
Observe the permissible pressure range given on the rating plate!
Pressure difference between Ports 1 and 3 ³ 2 bar
For temperatures below 0 °C, operation is limited to dry-air operation.
Take note of the voltage used; with alternating current, always
use the instrument socket Type 2506, or connect a rectifier into the circuit!
When screwing down the instrument socket onto the coil, ensure that the flat
seal is well seated!