background image

20

Installation

CAuTIoN!

danger when using volatile media!
If volatile media such as hydrogen peroxide (H2O2) or sodium
hypochlorite (NaCIO) are used, there is a serious risk of injury. The
media may evaporate causing a dangerous pressure increase in
the empty space between the ball and the housing.

If you have any questions regarding safety, please contact our

sales offices (telephone no. or address can be found on the last

pages of this manual).

installation in the pipeline

7.4.1.

procedure:

Check that the pipes which are to be connected to the valve are on

one level. This will prevent mechanical tension on the screw joint.
Unscrew the union nuts (

Fig. 2: /13) and push them onto the

pipes.
Bond, weld or screw the connecting parts (

Fig. 2: /12) of the plastic

ball valve onto the pipe ends.

Also follow the detailed instructions in chapter
7.2.Installation Process.

Place the plastic ball valve between the two connecting parts and

tighten the union nuts by hand.
Do not use a tool to tighten the union nuts as their surfaces could

be damaged.
If required, attach the pipeline with brackets or use the designated

bracket on the plastic ball valve.
Install the appropriate Dual Block locking device for the union nuts

(

Fig. 2: /16) on the housing.