beautypg.com

Burkert Type 2300 User Manual

Type 2300, Replacement instructions

background image

Austauschanleitung
Instructions de remplacement

Replacement Instructions

Type 2300

2/2-way angle-seat control valve
2/2-Wege Schrägsitzregelventil
Vanne de réglage à siège incliné 2/2 voies

Address / Adresse

Germany / Deutschland / Allemagne
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]

International
www.burkert.com → Bürkert → Company → Locations

Manuals and data sheets on the Internet:
www.burkert.com
Bedienungsanleitungen und Datenblätter im Internet:
www.buerkert.de
Manuel d'utilisation et fiches techniques sur Internet :
www.buerkert.fr

© 2013 Bürkert Werke GmbH
Replacement Instructions 1306/00_EU-ml_00810318 /
Original DE

SymbolS

designates a procedure which you must carry out.

Warning of serious or fatal injuries:

DAnGer!

In case of imminent danger.

WArnInG!

In case of potential danger.

Warning of minor or moderately severe injuries:

CAutIon!

Replacement paRt SetS

Replacement part sets for the angle-seat control valve Type 2300:
• Control cone set

consisting of control cone, dowel pin, graphite seal and lubricant.

• Sealing set for packing gland

consisting of the individual parts of the packing gland, graphite seal
and lubricant (the modified socket wrench is not included in the
sealing set).

• Spindle guide for packing gland

consisting of VA spindle guide, graphite seal and lubricant.

oveRview of Replacement paRt SetS

4

6

1

2

3

5

7

Item

Description

1

Control cone set

Graphite seal (packed)

2

Control cone

3

Dowel pin

4

Sealing set for packing gland SP10 / SP14

5

Sealing set for packing gland SP22

6

VA spindle guide for packing gland SP10 / SP14

7

VA spindle guide for packing gland SP22

english

note!

Damage to the seat seal or the seat contour!
• When removing the actuator, ensure that the valve is in open

position.

Control function A:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.

Using a suitable open-end wrench, place the wrench flat on the
pipe.

Unscrew the actuator from the valve body.

Actuator

Nipple

Valve body

Flats for open-end

wrench

Pilot air port

Exhaust air port 2

1

Replacing the contRol cone Set

DAnGer!

Risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
• Before removing a device, switch off the pressure and vent the lines.

WArnInG!

Risk of injury if the wrong tools are used!
It is dangerous to use unsuitable tools for installation work as the
device may be damaged.
• To remove the actuator from the valve body, use an open-end wrench,

never a pipe wrench.

Before the control cone set can be replaced, the actuator
must be removed from the valve body.

Remove the actuator from the valve body:

Clamp the valve body in a holding device
(applies only to valves which have not yet been installed).

english