16

Option: Min. /max. stroke limitation

8.

OPTION: MIN. /MAX. STROKE
LIMITATION
with optical position display

8.1.

Actuators D-50, E-63 und F-80

Loctite 274

Parts required

1 Spindle

2 Guide spindle

3 Nut, slotted

4 Bridge (actuator)

5 Cap screw

6 Transparent cap

7 Cover

8 Coupling

9 O-ring

10 O-ring

Fig. 6: Actuators D-50, E-63,

min. / max. stroke limitation with optical position display

8.1.1. Work to be carried out before

installation

DANGER!

Hazard due to high pressure!
• Interrupt the control air and fluid infeed before modifying the

devices and reduce the pressure in the fluid system.

Interrupt supplies of control air and medium.

Empty valve housing.

Unscrew transparent cap from actuator cover.

Screw out position indicator with Allan key (WAF5 or WAF8).

NOTE!

Damage to the actuators due to incorrect tool!
• Only the special wrench provided by Bürkert for the purpose

must be used to screw down the actuator cover.

• (see chapter on assembly accessories).

Screw off actuator cover with special wrench, counterbracing at
the sleeve.

8.1.2. Installation and commissioning

Screw coupling

⑧ onto valve spindle and secure with Loctite

274.

Hook spindle

① in coupling ⑧.

Grease spindle

①.