Assembly
Optical position indicator
Yellow = valve open
Actuator
Wrench flat for open-end wrench
(hexagonal)
Valve housing
Fig. 4:
Removing the actuator
8.3.2. Installing valve housing in pipeline
For welded housings:
→
Weld valve housing in pipeline system.
→
Check graphite seal and, if required, replace.
Graphite seal
Fig. 5:
Graphite seal
For other housing models:
→
Connect valve housing to pipeline.
8.3.3. Installing actuator on valve housing
DANGER!
Risk of explosion if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of explosion.
• In specific applications, e.g. oxygen or analysis applications, use
appropriately authorized lubricants only.
english
Type 2000 INOX
See also other documents in the category Burkert Accessories for water:
- Type 0125 (15 pages)
- Type 0121 (4 pages)
- Type 0330 (2 pages)
- Type 0331 (4 pages)
- Type 6012 (4 pages)
- Type 0127 (18 pages)
- Type 0131 (5 pages)
- Type 0141 (5 pages)
- Type 0142 (12 pages)
- Type 0145 (3 pages)
- Type 0174 (5 pages)
- Type 0211 (5 pages)
- Type 0212 (2 pages)
- Type 0212-B (18 pages)
- Type 0250 (64 pages)
- Type 0253 (2 pages)
- Type 0355 (2 pages)
- Type 0255 (15 pages)
- Type 0255 (2 pages)
- Type 8640 (119 pages)
- Type 8006 (34 pages)
- Type 8640 (2 pages)
- Type 8640 (55 pages)
- Type 0256 (15 pages)
- Type 0256 (2 pages)
- Type 0258 (72 pages)
- Type 0262 (5 pages)
- Type 0273 (6 pages)
- Type 0280 (5 pages)
- Type 0280 (2 pages)
- Type 0280 (12 pages)
- Type 0281 (2 pages)
- Type 0282 (2 pages)
- Type 0283 (2 pages)
- Type 0286 (4 pages)
- Type 0287 (15 pages)
- Type 0290 (2 pages)
- Type 0290 (14 pages)
- Type 0293 (18 pages)
- Type 0300 (6 pages)
- Type 0301 (6 pages)
- Type 0311 (2 pages)
- Type 0312 (6 pages)
- Type 6519 (2 pages)
- Type 6518 (57 pages)