Application conditions of the devices
5.8.
maximum permitted ambient 
temperature
Please	observe	the	maximum	permitted	ambient	temperature	indicated	
for	each	type	under	application	conditions	of	the	coil!
design
maximum permitted ambient
temperature
74.
-40 ... +40 °C
75.
-40 ... +50 °C
(-40 ... +55 °C when T3)
5.9.
Application in petrol pumps
Danger!
risk	of	explosion	by	opening	the	device!
•	 The	device	is	a	closed	system.	It	must	not	be	removed!
danger	of	explosion!
•	 If	devices	are	used	in	gasoline	pumps	to	control	gasoline	as		
Category 2, a valve body made of metal (brass, aluminum or
stainless steel) must be used.
The	devices	may	also	be	used	to	control	gasoline	in	Category	2	if	there	
is	no	air	and	no	oxygen	in	the	closed	system.
This	also	applies	to	starting	and	switching	off	the	system.
Model with over-
stretched coil
Block-screwed
model
The	solenoid	coils	are	mounted	on	the	fitting	using	either	4	cylinder	
head	screws	M4	x	58	(flange	model)	or	a	central	attachment		
M14	x	1.5	(overstretched	model).
The	solenoid	coils	may	be	removed	by	the	manufacturer	
only!
The valves always represent a closed system.
english
PTB 02 ATEX 2173 X