Electrical data 6.6. electrical connection – Burkert Type 0742 User Manual
Page 12

12
Technical Data
6.5.
Electrical data
type
74.
75.
temperature class
T4
T3 or T5
current type
AC/DC
AC/DC
nominal voltage
12 ... 240 V
12 ... 240 V
rated current
1,00 ... 0,028 A
0,63 ... 0,028 A
power limit in
equilibrium
10 W
7 W
6.6.
Electrical connection
identifi-
cation
design
internal
code
A *
Permanently installed rubber hose line of
type H05 RN-F3G0,75
Not
specified
L
** Terminal box with cable gland
M20 x 1.5 without fuse
JA02
Terminal box with threaded nipple
M20 x 1.5 without fuse
JA08
Terminal box with threaded nipple
NPT 1/2 without fuse
JA09
Terminal box with threaded nipple G 1/2
without fuse
JA10
K ***
** Terminal box with cable gland
M20 x 1.5 and fuse
JA01
Terminal box with threaded nipple
M20 x 1.5 and fuse
JA05
Terminal box with threaded nipple
NPT 1/2 and fuse
JA06
Terminal box with threaded nipple G 1/2
and fuse
JA07
* The connection line of the electromagnet type 7. must be permanently
installed in such a way that it is adequately protected from mechanical
damage.
** Cable gland according to separate type-examination certificate.
*** Fuse according to separate type-examination certificate.
english
PTB 02 ATEX 2173 X