beautypg.com

Electrical data 6.6. electrical connection – Burkert Type 0742 User Manual

Page 12

background image

12

Technical Data

6.5.

Electrical data

type

74.

75.

temperature class

T4

T3 or T5

current type

AC/DC

AC/DC

nominal voltage

12 ... 240 V

12 ... 240 V

rated current

1,00 ... 0,028 A

0,63 ... 0,028 A

power limit in
equilibrium

10 W

7 W

6.6.

Electrical connection

identifi-

cation

design

internal

code

A *

Permanently installed rubber hose line of
type H05 RN-F3G0,75

Not

specified

L

** Terminal box with cable gland
M20 x 1.5 without fuse

JA02

Terminal box with threaded nipple
M20 x 1.5 without fuse

JA08

Terminal box with threaded nipple
NPT 1/2 without fuse

JA09

Terminal box with threaded nipple G 1/2
without fuse

JA10

K ***

** Terminal box with cable gland
M20 x 1.5 and fuse

JA01

Terminal box with threaded nipple
M20 x 1.5 and fuse

JA05

Terminal box with threaded nipple
NPT 1/2 and fuse

JA06

Terminal box with threaded nipple G 1/2
and fuse

JA07

* The connection line of the electromagnet type 7. must be permanently

installed in such a way that it is adequately protected from mechanical
damage.

** Cable gland according to separate type-examination certificate.
*** Fuse according to separate type-examination certificate.

english

PTB 02 ATEX 2173 X