Place the 3 O-rings in the recess in the back of the valve. Make sure they are seated exactly!
Fix the valves with 2 screws each to the aluminium baseplate (tightening torque max. 0.5 Nm).
Mount the complete valve block on the wall or the standard rail.
Connect the supply and working lines.
Make the electrical connections to the pilot valves; observe the data on the nameplate!
ATTENTION!
Squeezing the O-rings will result in a leaky block!
Assembly
Hook the valve block with the upper groove in the standard rail.
Engage the lower clamps in the standard rail.
Tighten the screws on the clamps.
Disassembly
Loosen the clamping screws (approx. 4 turns).
Remove the block upwards from the standard rail.
Unscrew the 2 screws at the valve from the aluminium baseplate.
Remove the valve in the forward direction.
Take care of the O-rings.
Disassembly of valve Type 04540 from the aluminium baseplate
Fixing the valve block to a standard rail
Fixing the valve block to the wall
Fix the valve block with M6 screws directly to the wall.
Assembly of valve Type 04540 on the aluminium baseplate