English, Valve construction, Circuit functions of valves type 0450 – Burkert Type 0450 User Manual
Page 10: Media

8 - 8640-0450
T
ECHNICAL
D
ATA
english
•
5/2 or 5/3-way valve with 3/2-way pilot valve Type 6106 (standard and impulse versions)
•
5/2-impulse or 5/3-way valves have double width and occupy 2 valve spaces
•
Valve housing aluminium, black anodized, piston slide valve, service connections
•
Service connections 2 (B) / 4 (A), supply and vent connection 1 (P) / 3 (R) / 5 (S) with interior thread G 1/8 G 1/8
•
The valve can be assembled to a valve block on Aluminium Baseplate Type MP05
•
Any orientation, but preferably with magnet system above
•
Manual override knob for manual operating of the valve
Valve construction
H 5/2-way valve:
pilot control, de-energized, output port 2 exhausted,
various reset modes including impulse valve
L 5/3-way valve:
pilot control, in middle position all connections blocked
N 5/3-way valve:
pilot control, in middle position outputs ports 2 and 4
exhausted
Circuit functions of valves Type 0450
•
Compressed air, lubricated, unlubricated
•
Sealing material
POM/NBR
•
Permissible temperature range
Medium
- 10 to + 70 °C
Ambient
- 10 to + 55 °C
•
Operating pressure range
2 - 8 bar or 2 - 10 bar
ATTENTION!
Observe the permissible pressure range on the nameplate!
Pressure difference between connections 1 and 3
≥≥≥≥≥
2 bar
At temperatures below 0 °C, operation is limited to dried air.
Media
Example
permissible pressure
NOTE
By sealing a service connection, the 5/2-way valve may be simply converted into a 3/2-way valve:
Service connection 2
=>
Circuit function C
Service connection 4
=>
Circuit function D