Specifications:

Range:


Accuracy:

± 0.2% of range

Resolution:

LU27: 0.019” (0.5mm)

LU23: 0.039” (1mm)

LU28: 0.079” (2 mm)

LU28: 0.079” (2 mm)

Dead band:

LU27: 4” (10cm)

LU23/28/29: 8” (20cm)

Beam width:

LU27: 2” (5cm)

LU23/28/29: 3” (7.6cm)

Configuration:

WebCal® PC

Windows® USB 2.0

Memory:

Non-volatile

Supply voltage:

24 VDC (loop)

Consumption:

0.5 W

Loop resistance: 500 Ohms @ 24 VDC

Signal output:

4-20 mA, two-wire

Signal invert:

4-20 mA or 20-4 mA

Signal fail-safe: 4 mA, 20 mA, 21 mA,

22 mA or hold last

Process temp.:

F: -4° to 140°

C: -20° to 60°

Temp. comp.:

Automatic

Ambient temp.:

F: -31° to 140°

C: -35° to 60°

Pressure:

MWP = 30 PSI

Enclosure type: Type 6P encapsulated,

corrosion resistance &
submersible

Encl. material:

Polycarbonate

Trans. material:

PVDF

Cable jacket mat.: Polyurethane
Cable type:

4-conductor shielded

Cable length:

10’ (3 m)

Process mount:

LU27: 1” NPT (1” G)

LU23/28/29: 2” NPT (2”
G)

Mount. gasket:

Viton®

Classification:

General purpose

Compliance:

CE, RoHS

Approvals:

cFMu

Dimensions:

Side View / LU27 Series

Side View / LU23, LU28 and LU29 Series


LU27: 4" to 9.8'

(10 cm to 3 m)

LU23: 8" to 18.0'

(20 cm to 5.5 m)

LU28: 8" to 26.2'

(20 cm to 8 m)

LU29: 8" to 32.8'

(20 cm to 10 m)