Ack 0, Ack 1 – A&D Super Wash Down Scales SW-150KL User Manual
Page 35
33
Five-level comparator mode…Set the HIHI limit value.
Three-level comparator mode…Set the HI limit value.
(No reply for the function setting “
aCk 0
“.)
Set the six-digit value excluding the polarity and decimal point.
Command
H 2
, + 0 0 0 4 0 0 C
R
L
F
Reply
H 2
, + 0 0 0 4 0 0 C
R
L
F
Five-level comparator mode…Set the HI limit value.
Three-level comparator mode…Not used.
(No reply for the function setting “
aCk 0
“.)
Send the six-digit value excluding the polarity and decimal point.
Command
H 1
, + 0 0 0 3 0 0 C
R
L
F
Reply
H 1
, + 0 0 0 3 0 0 C
R
L
F
Five-level comparator mode…Set the LO limit value.
Three-level comparator mode…Not used.
(No reply for the function setting “
aCk 0
“.)
Send the six-digit value excluding the polarity and decimal point.
Command
L 1
, + 0 0 0 2 0 0 C
R
L
F
Reply
L 1
, + 0 0 0 2 0 0 C
R
L
F
Five-level comparator mode…Set the LOLO limit value.
Three-level comparator mode…Set the LO limit value.
(No reply for the function setting “
aCk 0
“.)
Send the six-digit value excluding the polarity and decimal point.
Command
L 2
, + 0 0 0 1 0 0 C
R
L
F
Reply
L 2
, + 0 0 0 1 0 0 C
R
L
F
Replies to the commands other than examples above when the function setting “
aCk 1
“ is
selected
.
The scale is not in a state where a command could be executed. Then, the scale will reply “I”.
Command
Z C
R
L
F
Reply
I C
R
L
F
The scale is not in a condition that zero operation is possible.
Command does not exist for the scale. Then, the scale will reply “?”.
Command
B C
R
L
F
Reply
? C
R
L
F
The scale received an undefined command.
When the function setting “
aCk 0
“ is selected, undefined commands are ignored
and no reply is sent.