beautypg.com

Ack 0, Ack 1 – A&D Super Wash Down Scales SW-150KL User Manual

Page 35

background image

33

‰

Five-level comparator mode…Set the HIHI limit value.

Three-level comparator mode…Set the HI limit value.

(No reply for the function setting “

aCk 0

“.)

Set the six-digit value excluding the polarity and decimal point.

Command

H 2

, + 0 0 0 4 0 0 C

R

L

F

Reply

H 2

, + 0 0 0 4 0 0 C

R

L

F

‰

Five-level comparator mode…Set the HI limit value.

Three-level comparator mode…Not used.

(No reply for the function setting “

aCk 0

“.)

Send the six-digit value excluding the polarity and decimal point.

Command

H 1

, + 0 0 0 3 0 0 C

R

L

F

Reply

H 1

, + 0 0 0 3 0 0 C

R

L

F

‰

Five-level comparator mode…Set the LO limit value.

Three-level comparator mode…Not used.

(No reply for the function setting “

aCk 0

“.)

Send the six-digit value excluding the polarity and decimal point.

Command

L 1

, + 0 0 0 2 0 0 C

R

L

F

Reply

L 1

, + 0 0 0 2 0 0 C

R

L

F

‰

Five-level comparator mode…Set the LOLO limit value.

Three-level comparator mode…Set the LO limit value.

(No reply for the function setting “

aCk 0

“.)

Send the six-digit value excluding the polarity and decimal point.

Command

L 2

, + 0 0 0 1 0 0 C

R

L

F

Reply

L 2

, + 0 0 0 1 0 0 C

R

L

F

Replies to the commands other than examples above when the function setting “

aCk 1

“ is

selected

.

‰

The scale is not in a state where a command could be executed. Then, the scale will reply “I”.

Command

Z C

R

L

F

Reply

I C

R

L

F

The scale is not in a condition that zero operation is possible.


‰

Command does not exist for the scale. Then, the scale will reply “?”.

Command

B C

R

L

F

Reply

? C

R

L

F

The scale received an undefined command.


‰

When the function setting “

aCk 0

“ is selected, undefined commands are ignored

and no reply is sent.