beautypg.com

Function list – A&D Super Wash Down Scales SW-150KL User Manual

Page 25

background image

23

12.3. Function list

Item

Parameter

Description

Š

0

Auto power-off disabled

Auto power-off function

poff

1

Auto power-off enabled

Turns the power OFF
automatically

0

Normal (1/3,000)

Š

1

High (1/6,000 or 1/7,500)

Weight display
resolution

re5o

2

Maximum (1/12,000 or 1/15,0 00)

Changes the

minimum display

Š

0

kg

Weighing unit

Ut-g

1

g

0

Zero tracking function disabled

Zero tracking

trc

Š

1

Zero tracking function enabled

Tracks the zero drift

Š

0

±0.5d (width 1d)

1

±1.0d (width 2d)

Stability band
width

5t-b

2

±2.0d (width 4d)

0

0.5 second

Š

1

1.0 second

Stability
detection time

5t-t

2

2.0 seconds

Conditions to turn the
STABLE indicator on

d = minimum display

in kg

0

Weak stability / fast response

Š

1

Normal stability / normal response

Stability
Response speed

Cond

2

Strong stability / slow response

Filtering

Š

0

2400 bps

1

4800 bps

Serial interface
baud rate

bp5

2

9600 bps

Š

0

7 bits / EVEN

1

7 bits / ODD

Serial interface
data bits / parity

btpr

2

8 bits / Non parity

Š

0

Stream mode / Command mode

1

Command mode only

2

Print switch mode /

Command mode

3

Auto-print mode +/- data / Command mode

Serial interface
Data output
mode

prt

4

Auto-print mode + data/ Command mode

Š

0

RS-232C

1

RS-422

Serial interface
Type

5if

2

RS-485

Serial interface
Address

adr

##

## = 00 to 99
(Factory setting: ## = 01)

0

No reply except data to commands

Serial interface
Response

aCk

Š

1

Reply to commands

Only when the

options, RS-232C or

RS-422/485, are

used.

Š

0

Five-level (LOLO, LO, OK, HI, HIHI)

Comparator mode

Cp-l

1

Three-level (LO, OK, HI)