13.2.3. Command mode
In the command mode, the scale is controlled by commands that come from an
external device such as a personal computer.
Command List
Command Description
Remarks
Q
Send data immediately.
Z
Zero the scale when the weight is stable.
Same as the ZERO switch.
T
Tare the scale when the data is stable.
Same as the TARE switch.
U
Switch the weighing unit.
Same as the UNITS switch.
?H2
When the five-level comparator mode is used:
Send the current HIHI limit value.
When the three-level comparator mode is used:
Send the current HI limit value.
?H1
When the five-level comparator mode is used:
Send the current HI limit value.
When the three-level comparator mode is used:
Not used
?L1
When the five-level comparator mode is used:
Send the current LO limit value.
When the three-level comparator mode is used:
Not used
?L2
When the five-level comparator mode is used:
Send the current LOLO limit value.
When the three-level comparator mode is used:
Send the current LO limit value.
Send a setting value.
Function settings
Five-level (
Cp-l 0
)
Three-level (
Cp-l 1
)
H2
When the five-level comparator mode is used:
Set the HIHI limit value.
When the three-level comparator mode is used:
Set the HI limit value.
H1
When the five-level comparator mode is used:
Set the HI limit value.
When the three-level comparator mode is used:
Not used.
L1
When the five-level comparator mode is used:
Set the LO limit value.
When the three-level comparator mode is used:
Not used.
L2
When the five-level comparator mode is used:
Set the LOLO limit value.
When the three-level comparator mode is used:
Set the LO limit value.
Set the six-digit value excluding