beautypg.com

A&D Super Wash Down Scales SW-150KL User Manual

Page 28

background image

26


1. Disconnect the AC power cable from the electrical outlet.
2. Loosen the M4 screws and remove the rear cover of the display.

Note: Take care not to drop the display.

3. Connect the wires inside the display to the battery with much care so that nothing

touches the switches.

Note: Be sure to connect the RED wire to the positive (+ / RED) terminal and

the BLACK wire to the negative (- / BLACK) terminal. Or there is a risk
of explosion.

4. Install the battery into the display.
5. Attach the rear cover to the display and secure it with the screws loosened at step 2.
6. Connect the AC power cable to the electrical outlet.

7. Press the ON/OFF switch and check that the scale turns ON.

8. Disconnect the AC power cable

and check that the scale works normally.

13.1.2. Charging the battery

‰

When the weight display shows “

lb

” (Low battery), the battery voltage is low and

should be recharged. Turn the scale OFF and connect the AC power cable to an
electrical outlet. The charging process will start.

‰

Charging will be performed when the AC power cable is connected to an electrical

outlet and the scale is turned OFF. If the scale is turned ON, trickle charging will be
performed.

‰

The scale can be used while the battery is charging. After fully charged, the scale

will change the charging process to trickle charge automatically.

Notes

Charge the battery at a temperature between 0°C (32°F) and 40°C (104°F),

preferably, at a range of 5°C (41°F) to 35°C (95°F) .

Charge the battery when using for the first time.
The battery must be recharged regularly, every 3 to 6 months, if the scale is

not used for a long period of time. More frequent recharging is required in a
warmer area.