Ack 1, Ack 0 – A&D Super Wash Down Scales SW-150KL User Manual
Page 34
32
Command examples (“_” indicates “Space” (20H).)
The examples below are for the function setting “
aCk 1
“ (Reply to commands).
Request the weight data.
Command
Q C
R
L
F
Reply
S T , + 0 0 1 2
.
3 4 5 _ k g C
R
L
F
Stable positive data
U S ,
+ 0 0 0 7
.
8 9 0 _ k g C
R
L
F
Unstable positive data
O L
,
+ 9 9 9 9
.
9 9 9 _ k g C
R
L
F
‘E’ display
Zero the scale. (No reply for the function setting “
aCk 0
“.)
Command
Z C
R
L
F
Reply
Z C
R
L
F
The scale is in a condition that zero operation is possible.
Tare the scale. (No reply for the function setting “
aCk 0
“.)
Command
T C
R
L
F
Reply
T C
R
L
F
The scale is in a condition that tare operation is possible.
Switch the weighing unit. (No reply for the function setting “
aCk 0
“.)
Command
U C
R
L
F
Reply
U C
R
L
F
Switch the weighing unit to the next weighing unit.
Five-level comparator mode…Send the current HIHI limit value.
Three-level comparator mode…Send the current HI limit value.
Command
? H 2 C
R
L
F
Reply
H 2
, + 0 0 0 4 0 0 C
R
L
F
Five-level comparator mode…Send the current HI limit value.
Three-level comparator mode…Not used
Command
? H 1 C
R
L
F
Reply
H 1
, + 0 0 0 3 0 0 C
R
L
F
Five-level comparator mode…Send the current LO limit value.
Three-level comparator mode…Not used
Command
? L 1 C
R
L
F
Reply
L 1
, + 0 0 0 2 0 0 C
R
L
F
Five-level comparator mode…Send the current LOLO limit value.
Three-level comparator mode…Send the current LO limit value.
Command
? L 2 C
R
L
F
Reply
L 2
, + 0 0 0 1 0 0 C
R
L
F