Connecting trunk pairs to media gateway, Using jumper wires to establish 3-pair modularity – Avaya 03-300686 User Manual
Page 67

Installing and administering the patch cord/jumper
Issue 3 January 2008
67
Connecting trunk pairs to media gateway
using jumper wires to establish 3-pair modularity
Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks
modularity for trunk pairs for 3-pair Tie trunks
on page 68 show trunk pairs connected to the
media gateway with jumper wires to establish 3-pair modularity.
To connect the trunk pairs to the purple field:
1. Connect B25A cables between the network interface and the sneak fuse panels. See
Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks
2. Connect A25D/B25A cables from the sneak fuse panels to the 110-type terminal block-type
connecting block connectors in the green field.
3. Connect 1-pair patch cords/jumper wires from each 110-type terminal block row in the green
field to the 110-type terminal block rows in the purple field for 1-pair central office (CO)
trunks or in
Figure 33: 3-pair modularity for trunk pairs for 3-pair Tie trunks
3-pair tie trunks.
Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks
Figure notes:
1. Green Field
2. 1-Pair Jumpers
3. Pairs
4. Purple Field
1
2
3
4
5
6
7
8
1
4
7 10 13 16 19 22
1
4
7 10 13 16 19 22
1
4
7 10 13 16 19 22
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
r758425b MMR 031496