8-6. COMMUNICATION PORTS
8-7. TRIGGER
8-8. ENVIRONMENTAL
•
RS232 (on DB9 female connector)
Data Rate :
9600 Bauds, 8 data bits, 1 stop bit, no parity bit, no flow control.
Pin-out :
PIN #
FUNCTIONS
2
Tx1 (transmit data to the control device)
3
Rx1 (receive data from the control device)
4
Rx2 (receive data from the display device)
5
GROUND (Gnd)
8
Reserved for manufacturer.
9
Tx2 (transmit data to the display device)
•
LAN
Protocol :
TCP (Transmission Control Protocol) / UDP (User Datagram Protocol).
Data Rate :
10 / 100 Mbps.
LED functions (on RJ45 connector) :
Left LED
Right LED
Meaning
OFF
OFF
No link
OFF
ON
100 BASE-T link.
ON
OFF
10 BASE-T link.
Connector :
Jack 3.5 mm female.
Command levels :
ON
= + 12 Vdc trigger.
OFF
= 0 Vdc.
Output Current :
0.1 A max at + 12 Vdc.
NOTE : This output is activate with the AC Power Switch (ON/OFF).
Power Supply :
Internal CE / UL / CSA / IEC 950 (50 W), universal, automatic.
Input : 100 VAC to 250 VAC; 50-60 Hz; I = 1 A Max.
Storage Temperature :
- 40 °C to + 70 °C (- 40 °F to + 158 °F).
Operating temperature :
0 °C to + 50 °C (32 °F to 122 °F).
Hygrometry :
10% to 80% (without condensation).
Dimensions :
D 265 x W 482 x H 44 mm / D 10.4” x W 19” x H 1.74”.
Compatible with the 19” rack (height = 1 unit).
Weight :
3.5 kg / 7.7 lbs.
+ 12 Vdc
Ground
Jack 3.5 connection