6.1.1 Self-diagnostics

The machine can perform self-diagnostics to check the
LED’s on the control panel and make sure the encoder
reads correctly.

To perform this operation, view the SETUP menu.

In the self-diagnostics sequence, all the LED’s on the panel
light up for a few seconds in order to check operation. When
the LED’s go out, the machine automatically moves on to the
encoder reading phase. When the wheel is turned manually
(forwards and backwards), the display shows its exact posi-
tion. The value lies between 0 (zero) and 255.

6.1.2 Type of display of unbalance phase

The type of display of the unbalance phase can be selected,
different from what is described in the manual to date.

Display the SETUP menu:

P

1. ress

to view the unbalance phase

display

function

P

2. ress

to modify the type of unbalance

phase display and confirm

In this case the unbalance phase is indicated in the fol-
lowing way:

- Inside correction

- Outside correction

MEASURING RESULT OF SPLIT UNBALANCE:
Each weight to be applied has its own display (1 for the
inside and 2 for the outside in ALUS).

Unbalance inconsistent NOT in position

Correction position 1

Correction position 2

INFORMATION

The standard type of display is type 1, i.e. that

described throughout the manual.