Setup, 1 language, 2 screen-saver time – CEMB USA ER85 (A) User Manual
Page 22: 3 acoustic signal, 4 setting the clock, 5 eccentricity setup, Options, 1 radial runout, 2 laser, 3 rim interior light
![background image](/manuals/326136/22/background.png)
22
7
1
-
Use and maintenance manual Rev. 09-2013
ENGLISH
7. Setup
The Setup screen provides the user with many possibilities
required for presetting the machine according to his own
requirements. Such settings remain unaltered even when
the machine is switched off.
The following buttons are enabled:
return to previous window
return to Measurement screen
for selection of the parameter.
7.1 LANGUAGE
This function allows selecting the language to be used for
displaying descriptive and diagnostic messages regarding
machine operation.
7.2
SCREEN-SAVER TIME
If this function is enabled, the screensaver will automa-
tically be activated when the machine is not used for a
certain period of time. This function can be disabled by
setting it to 0.
7.3 ACOUSTIC SIGNAL
When “ON” is selected, the sending of an acoustic signal
(beep) is enabled in the following cases:
▪ when any push button is pressed;
▪ when dimensions are acquired in automatic mode;
▪ when the correct angular position for weight application
is reached in the Measurement screen;
▪ when the correct angular position for weight application
is reached in the Position Repeater screen.
7.4
SETTING THE CLOCK
Used to set date and time correctly. Follow the instructions
on the screen.
7.5 ECCENTRICITY SETUP
Enables display of a menu where the following parameters
can be set:
Eccentricity unit of
measure
It is possible to select display of
eccentricity measurements in mm
or inches.
First harmonic limit
The first harmonic limit beyond
which it is felt suitable to rotate
the tyre on the 180° rim. Recom-
mended Limit = 1.2 mm.
Matching
At the end of the spin, enables/
disables display of the window
that recommends optimising the
eccentricity for values greater than
the first harmonic limit set.
7.6 OPTIONS
7.6.1 Radial runout
Enables/disables radial eccentricity measurement.
7.6.2 Laser
If enabled, the weight application position is indicated in
correspondence to the laser (5 o’clock) to facilitate rim
cleaning and adhesive weight application.
7.6.3 Rim interior light
Enables/disables the rim interior light.
7.6.4 Wheel locking enable
Enables/disables wheel locking in the correction position
(
WHEEL LOCKING
).
The possible options are:
OFF: disabled
ON: enabled
7.6.5 Gauge locking enable
Enables/disables distance gauge locking when the correct
distance has been reached to apply the adhesive weight to
correct the unbalance.
To release the gauge, lower it to below 10” diameter.
7.6.6 Tyre train
Setup