TG66B

A

B

C

D

F-

IGN

GND

B+

+

-

30VDC

ADJUSTABLE

POWER SUPPLY

+28VDC

N3012 REGULATOR

LAMP

30V 1W MIN.

E

A

B

C

D

E

REG TURN OFF

SW1

(IGN)

SW2

(MOMENTARY)

*AMPHENOL MS3111E14-5S-027 OR EQUIVALENT

R1

45Ω

11W

1. SET UP AS DEMONSTRATED IN SCHEMATIC DIAGRAM. SW2 IS MOMENTARY, NORMALLY OPEN.

2. MAKE SURE IGN SWITCH (SW1) IS OFF.

3. TURN ON ADJUSTABLE DC POWER SUPPLY.

4. SET POWER SUPPLY TO 24.0 VDC.

LAMP SHOULD BE OFF. IF LAMP IS ON, REGULATOR IS DEFECTIVE.

5. TURN ON IGN SWITCH.

LAMP SHOULD NOW BE ON. IF LAMP IS NOW OFF, REGULATOR IS DEFECTIVE.

6. RAISE VOLTAGE ON ADJUSTABLE POWER SUPPLY .

LAMP SHOULD TURN OFF WHEN POWER SUPPLY VOLTAGE IS RAISED HIGHER THAN

REGULATOR SET POINT (27.0 -29.0 VDC). IF NOT, REGULATOR IS DEFECTIVE.

7. BRIEFLY PRESS SW2. LAMP SHOULD BE OFF WHILE SW2 IS PRESSED, AND TURN

BACK ON WHEN BUTTON IS RELEASED. IF NOT, REGULATOR IS DEFECTIVE.

N3012 REGULATOR TEST SETUP DIAGRAM

N3012/N3210 Regulators

General Test Procedures